GD-2136H Cable Fault Locating System

GD-2136H Cable Fault Locating System

Brief Description:

GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables.

 


Product Detail

Product Tags

GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables.

The system contains below units:
1. GD-2131H Impulse Generator
2. GD-2132 Cable Fault Locator
3. GD-2133 Cable Fault Tester
4. Other accessories

GD-2131H Impulse Generator

GD-4136H Cable Fault Locating System 01

It's used to generate HV impulse when using impulse flashover method to detect high impedance fault.

Features

Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased.
If working together with GD-2133 Cable Fault Tester, there are two locating ways:
a. Low voltage pulse: If only using GD-2133, open circuit and low impedance grounding faults of cable can be located, and the length of cable can be measured or wave speed of cable can be detected.
b. High voltage flashover: The discharging pulse voltage waveform of fault point is sampled by discharging sphere gap, which can locate fault distance.
Generate impulse of fixed frequency. If working together with GD-2132 Cable Fault Locator, there are following functions:
a. The audio method is used to complete the precise location of the general high-resistance and flashover fault points.
b. To pinpoint cable’s route, identify special cable.
c. For metallic breakdown(dead grounding), using magnetic-field measurement to locate accurately.
It also can be used in DC HV withstand test.

Specifications

Input power supply: AC 220V,50Hz
Output voltage: DC 0-32kV (adjustable)
Rated power: 2000VA
Max.energy: 2048J, 4uF
DC flashover voltage: 32kV
DC flashover current: 63mA
Max.impulse current: 500mA
Discharging method: DC HV, one time, cycle
Cycle discharging time: 3-6 seconds
Environmental temperature:0-40℃
Humidity:<75% RH
Altitude:<1000m
Insulation level: A
Dimension: 430*540*410mm
Weight:about 31kg.

GD-2132 Cable Fault Locator

GD-2136H Cable Fault Locating System001

Including transmitter, receiver, Inductive probe, potential type detection frame.It is suitable to test all kinds of power cable with metallic conductor.
Its main function is locating poor insulation point, detecting circuit and depth of power cable.

Features

High sensitivity
Low static drift
High accuracy of locating
Anti-interference
LCD screen to show signal and status
Built-in rechargeable Li-battery

Specifications

Tracing and locating distance: local cable 3km, other cable up to 20km
Locating impedance range: 0-5MΩ.
Locating accuracy: ≤±10cm.
Detection cable depth: <3m.

GD-2133 Cable Fault Detector

GD-2136H Cable Fault Locating System002

It can test faults of high-impedance flashover, high-low resistance grounding, short-circuit, cable disconnection, poor connection for all kinds of power cables (voltage degree 1kV-35kV) , local cable, communication cable, coaxial-cable and metal overhead line.
It also can measure cable’s length and propagation speed of electric wave speed on the cable.

Features

Safe, prompt and accurate testing. It uses LV impulse method and HV flashover detection, which test all kinds of cable faults. Especially for the flashover and high impendance faults of cables, it can be directly tested without burning through; if equipped with a acoustic measurement locator, the precise position of the fault can be accurately determined.
Using high speed data sampling technology. A/D sampling speed is 100Mhz, to make the reading resolution of the instrument is 1m and the detection blind area is 1m.
Wave form and data automatically display on big LCD screen.
Wave form and parameter storage, recall function.
Function of comparing testing waveform of cable fault with normal waveform.
Wave form extending function.
Directly show fault point and testing point direct distance or relative distance.
Modify speed of propagation any time according to different testing cables.
Built-in rechargeable battery. Small size, portable to carry.

Specifications

Max.testing distance: 15km(Open wire up to 100km).
Blind detection: 1m
Resolution: 1m
Power consumption: 5VA
Environmental temperature: 0-40℃(limit temperature:-10℃-50℃)
Relative humidity: 40℃(20~90) %RH
Atmospheric pressure: 86-106Kpa
Size: 275*220*160mm
Weight: 1.8kg

Other accessories

GD-2136H Cable Fault Locating System003

Other accessories include AF Stethoscope, Headphones, Grounding Pin, PD Locating Rack, RF Tracking Rod.